KCD2-SR-EX2安全栅为数字量输入安全栅(DI),双通道,适用于传感器,接近开关等。启栅(上海)自动化设备有限公司供应倍加福安全栅, 倍加福隔离器,倍加福浪涌保护器,提供技术咨询,欢迎来电咨询,陈小姐 。
KCD2-SR-EX2安全栅General specifications |
Signal type |
Digital Input |
Functional safety related parameters |
Safety Integrity Level (SIL) |
SIL 2 |
Supply |
Connection |
Power Rail or terminals 9+, 10- |
Rated voltage |
19 ... 30 V DC |
Ripple |
≤ 10 % |
Rated current |
≤ 30 mA |
Power dissipation |
≤ 600 mW |
Power consumption |
≤ 600 mW |
KCD2-SR-EX2安全栅Input |
Connection side |
field side |
Connection |
terminals 1+, 2-; 3+, 4- |
Rated values |
acc. to EN 60947-5-6 (NAMUR) |
Open circuit voltage/short-circuit current |
approx. 10 V DC / approx. 8 mA |
Switching point/switching hysteresis |
1.2 ... 2.1 mA / approx. 0.2 mA |
Line fault detection |
breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA |
Pulse/Pause ratio |
min. 20 ms / min. 20 ms |
KCD2-SR-EX2安全栅Output |
Connection side |
control side |
Connection |
terminals 5, 6; 7, 8 |
Output I |
signal ; relay |
Output II |
signal ; relay |
Contact loading |
253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 30 V DC/2 A resistive load |
Minimum switch current |
2 mA / 24 V DC |
Energized/De-energized delay |
≤ 20 ms / ≤ 20 ms |
Mechanical life |
107 switching cycles |